Part Number Hot Search : 
BU2727DX 15KP110 AXE25 KB1365 LC5864H G2030 MOC3063 E100A
Product Description
Full Text Search
 

To Download 8731-10 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  recorders wave comparator 8730 -10 /8731 -10 simple operation for quick pass/fail evaluation the wave comparators 8730 -10 /8731 -10 are purpose-designed instruments focusing on the superb waveform evaluation functions of the hioki memory hicorder series. specifically engineered in shape and functionality for seamless integration into production lines, the units are reasonably priced and easy to operate. compared to the more expensive multi-functional devices, the 8730 -10 /8731 -10 can accomplish a specific number of tasks with optimum efficiency. define a range and perform area evaluation, conduct numeric evaluation using upper and lower thresholds, or perform both of these functions all at the same time. enhance your production lines ideal for automatic testing in manufacturing environments
use the wave comparator for evaluation or store data for subsequent pc analysis - features - 2 what the hioki 8730 -10 /8731 -10 wave comparator can offer you: how the wave comparator has answered customer demands: the power of the memory hicorder is ideal for waveform evaluation, but integration into a control rack is difficult... we are looking to replace our old oscilloscopes used for visual monitoring, but we have a budget to meet... we've been using waveform evaluation instruments made by a control equipment manufacturer, but we can't store our data... our existing evaluation devices can't sample at higher rates... compared to the hioki memory hicorder 8835 -01 , waveform evaluation can be implemented at less than half the cost. operation flow is suitable for a production line environment. the memory capability of the multi-function memory hicorder has been streamlined for a single purpose. the setup screen employs windows-like pull-down menus for easy operation. low price and easy operation all operation switches and the display screen are arranged on the front panel, while the measurement input and control input/output connectors are located on the rear. the metal plate enclosure is flat on all sides to facilitate installation in a rack or a control panel. handles and feet are removable and can be mounted on the top if desired. physically designed for integration in production lines the sheet key switches have a flat surface and are accommodating to environments where grease or other contaminants exist. there are no openings between the controls and the unit chassis, so that the keys cannot be gummed up by dust, etc. the pc card slot on the front panel is equipped with a lid that provides basic dust proofing, which automatically closes when a pc card is inserted. resistant to tough working environments the external control connectors are isolated and allow connection also of a sequencer or other device with separate ground potential. if 24v dc is externally supplied, the control signals can operate at 24v. using the internal isolated 5v power supply for control is also possible. separate evaluation result output signals are provided for area and numeric evaluation. the two-channel model has a dedicated output for each channel. versatile external control data compatibility with the hioki memory hicorder 8835 -01 also makes it easy to display and print waveform data on the 8835 -01 , as well as conduct further data analysis. an evaluation area created on the memory hicorder 8835 -01 can be used or edited on the wave comparator 8730 -10 /8731 -10 . conveniently store data on pc cards the high sampling speed of the 8730 -10 / 8731 -10 is ideal for not only conventional mechanical systems but also electrical applications. the sampling frequency is 1/100 of the time axis range, resulting in 1- s sampling at 100 s/div. high-speed operation with 1m-sample/second
3 suitable for a wide range of uses. realize your own ideas. - application examples - machining precision is an important factor for assuring that driving force transmission gears mesh smoothly. torque fluctuations that arise during gear rotation can be measured and evaluated with the tsb ljmolo . automatic storing of waveform data for each sample makes data handling simple and quick. gear pre-load testing simply monitoring the current value often is not enough to evaluate the quality of a welding step. especially in automated lines where welding robots are used, evaluation of current waveform patterns is highly useful for checking and maintaining quality. welding quality check la rge handle for convenient por tability and transport. by angling the feet, the instrument can be positioned as desired for easy viewing. the wave comparators as seen installed in a control panel. please contact your local eflhf distributor for details. screw-on type feet can be easily removed. use the feet when placing the unit directly on a work surface. w hen mounting the unit on top of a control installation, screw fastening is possible by removing the plastic extensions and fitting the supplied left/right brackets. remove t he ha nd le a nd fe et for e a sy r a ck- mounting. versions to match either jis or eia standards are available. please contact your local eflhf distributor for details. .11jj /55jj .6-jj jpp 540- .- 7mmolu+0+3hd 540. .- 7mmolu+0+4hd (protective cover can be easily replaced if scratched) moapilq) type ii (with dust cover) .--/1-sfkibq (for screw-type connectors, please contact your local hioki distributor.) buqbokilkqolij0pobtqbojfkip (all input and output terminals are isolated from chassis) op/0/fkqbocb for remote control via a pc jbprobjbkqfkmrq qbojfkiptfqej0+2pobtp (isolated from each other and from chassis) screw type terminals are provided for easy wiring in production lines. if desired, specifications can be changed to bnc connectors. (contact your local eflhf distributor.) full isolation of all inputs enhances safety. .-pbiklkkbqlo for remote control via a pc pebbqhbvptfqebpobfjmbosflrpqlafoq wavefor m evaluation can be used to test whether a motor is operating normally. to do this, the actual waveform is compared to the control signal tolerance range. because t h e 5 4 0 - .- , 5 4 0 . .- a l lows st o r i ng of measurement data on a pc card, test data management can be implemented easily. motor operation testing x-y waveforms such as pressure/flow of a pump or pressure/stroke of a hydraulic press can be tested with the two-channel model 540. .- . the two inputs are suitable for x-y waveform measurement, and lissajous and other donut-shaped patterns can also be evaluated. hydraulic pressure testing
4 basic steps for area evaluation - operation examples - this is a fail result screen. the background is red, making the status easy to discern also from a distance. the "configure" menu at the top of the screen opens a list for controlling the time axis and making other settings. in the above example, 1div = 100s is selected. operation is very simple, using the cursor keys while watching the screen. to accept a setting, press set. to switch between different screens, use the menu keys at the top. measure a "good" waveform and use it to create an evaluation area. load the measured waveform into the "editor" window. (you can also create a new area from scratch without loading a waveform.) based on the loaded waveform, create an evaluation area by expanding the graph in the vertical and horizontal plane. the amount of shift is specified in div increments. by placing a box frame around a section, you can enlarge or reduce a specific segment of the area. simultaneously perform area and numeric evaluation. the screen shown below is an example for a pass result, using a green background. the overall evaluation result is shown at the top left, with details shown below this and numeric results displayed at the bottom of the screen. simple operation the "unit" menu at the top of the screen opens a list for controlling the voltage range and making other settings. in the above example, 1div = 1v is selected.
5 model 8731 -10 has two inputs for simultaneous evaluation of two waveforms - operation examples - rear view (input terminals) front view (2-channel evaluation example) full screen display example tiled screen display example: evaluation is still performed at full screen resolution, so there is no drop in accuracy. evaluating a time axis waveform using a donut- shaped are a : fail evaluation of a pulse with insufficient amplitude using 2-channel input for x-y lissajous waveform evaluation: vertical and horizontal voltage input allows lissajous waveform evaluation. (only with model 8731 -10 ) when tiling the screen horizontally, display resolution is reduced by a factor of 2, but... the inputs of model 540. .- (2-channel model) are shown below. the m3.5mm screw terminals are convenient when designing the wiring layout of a production line. for different requirements, specifications can also be changed to bnc connectors. (please contact your local hioki distributor for details.) for safety, all inputs are isolated from chassis ground and from each other. two channels for further enhanced performance when performing 2-channel evaluation with the 540. .- (2-channel model), you can tile the screen horizontally into two sections. on screen, this means that display resolution is halved, but evaluation precision is not affected. the internal processing memory continues to perform highly accurate evaluation using the full screen resolution. evaluation screen can be divided into two windows without impairing resolution because area evaluation is based on screen display pixels, complex donut-shaped patterns such as shown at right can also be evaluated. evaluation devices from other manufacturers use a / d conversion and base their a rea assessment on digital values. therefore, they can only judge whether nor not the upper and lower limits have been exceeded. models 540- .- and 540. .- on the other hand can also perform fail evaluation in the center of the range, something that is not possible with competing products. (x-y measurement is possible only with model 540. .- ) time axis evaluation of x-y lissajous waveform and donut-shaped patterns
6 time axis sampling period 8730 -10 (1 ch)/memory capacity 50 kw maximum recording length 500 div 8731 -10 (2 ch)/memory capacity 50 kw/ch maximum recording length 500 div 100 s/div 1 s 0.05 s 0.05 s 200 s/div 2 s 0.1 s 0.1 s 500 s/div 5 s 0.25 s 0.25 s 1ms/div 10 s 0.5 s 0.5 s 2ms/div 20 s 1 s 1 s 5ms/div 50 s 2.5 s 2.5 s 10ms/div 100 s 5 s 5 s 20ms/div 200 s 10 s 10 s 50ms/div 500 s 25 s 25 s 100ms/div 1ms 50 s 50 s 200ms/div 2ms 1 m 40 s 1 m 40 s 500ms/div 5ms 4 m 10 s 4 m 10 s 1s/div 10ms 8 m 20 s 8 m 20 s 2s/div 20ms 16 m 40 s 16 m 40 s 5s/div 50ms 41 m 40 s 41 m 40 s 10s/div 100ms 1 h 23 m 20 s 1 h 23 m 20 s 30s/div 300ms 4 h 10 m 0 s 4 h 10 m 0 s 1min/div 0.6s 8 h 20 m 0 s 8 h 20 m 0 s 2min/div 1.2s 16 h 40 m 0 s 16 h 40 m 0 s 5min/div 3.0s 41 h 40 m 0 s 41 h 40 m 0 s krjbofmolbppfkdkabsirqflk)aqpqlobmfifqv) ljjrkfqflkobav lmboqflkbujmibp measurement data ca n be stored on pc ca rds wh ich is convenient for archiving test data for production lines. a lan connector (10base-t) and rs-232c interface are provided as standard features. this lets you link the units to a pc network for easy access to important data. ( lan communicator 9333 is required to save data on a pc network, sold separately.) lksbkfbkqaqpsbkaqokpcbocrkqflkp choice of four different types of numeric evaluation functions available. upper and lower limits can be set against which the results of numeric processing are to be compared. besides maximum and minimum values, many other processing items (total 20 items) are also provided. dual evaluation capability means that area evaluation and numeric evaluation can be performed at the same time. the evaluation result screen shows the overall pass/fail result at the top left, and details on area evaluation and numeric evaluation 1 - 4 below this. krjbofmolbppfkdkabsirqflkcrkqflkp the internal memory of the unit holds information on up to 16 different evaluation areas. separate area evaluation settings can be stored for each channel. memory slots are numbered a01 - a16 and can be selected freely. a reduced size graph of the area shape is shown besides each selection, making it easy to pick the one you want. in addition, 16 different setup parameters can be stored in the internal memory and selected also via external control or key operation. pqlobbsirqflkobaqkapbqrmmojbqbopcloobmbqmmifqflkp internal memory storage capacity pc card type ii slot with dust cover (front panel) c o m m u n i c ati o n c o n n e c to r s p rov i d e d a s sta n d a rd equipment (rear panel)
7 output timing of evaluation result - how it works - external dc power can be 12v or 24v, and control signal input also operates at this voltage. using the internal isolated 5v power supply for control is also possible. because the terminals are isolated from chassis ground, connection of a sequencer, relay bank, or other device with separate ground potential presents no problem. external control connectors insulated from chassis the diagram below shows the evaluation output cycle when performing area evaluation only for a 1khz sine wave signal. when auto store is selected, data store processing occurs after the evaluation processing step. the evaluation time and evaluation cycle for numerical processing depend on the processing type and recording duration, and also on the evaluation waveform. evaluation result output timing trigger mode: continuous evaluation time: 70 ms max. (1-channel evaluation), 80 ms max. (2-channel evaluation) evaluation cycle: 200 ms max. (1-channel evaluation), 250 ms max. (2-channel evaluation) unit operation stop trigger standby get waveform evaluation processing display processing trigger standby get waveform trigger activated trigger activated okarea ngarea judgeout trigout storage busy measurement start measurement stop trigger mode: single unit operation stop trigger standby get waveform evaluation processing display processing stop trigger activated okarea ngarea judgeout trigout storage busy measurement start clear previous evaluation result evaluation result output clear evaluation result clear previous evaluation result evaluation result output store evaluation result setup: ? time axis range: 100 s/div ? recording length: 10div ? display format: 1screen ? no lan connection ? a/b cursor display set to off external control connectors provided as standard equipment (rear panel)
8 head office : 81 koizumi, ueda, nagano, 386-1192, japan tel +81-268-28-0562 / fax +81-268-28-0568 e-mail: os-com@hioki.co.jp hioki usa corporation : 6 corporate drive, cranbury, nj 08512 usa tel +1-609-409-9109 / fax +1-609-409-9108 e-mail: hioki@hiokiusa.com distributed by all information correct as of sep. 10, 2007. all speci?cations are subject to change without notice. 8730e4-79b-03p printed in japan hioki (shanghai) sales & trading co., ltd. : 1904 shanghai times square of?ce, 93 huai hai zhong road shanghai, p.r.china postcode: 200021 tel +86-21-6391-0090/0092 fax +86-21-6391-0360 e-mail: info-sh@hioki.cn beijing of?ce : a-2602 freetown, 58 dong san huan nan road beijing, p.r.china postcode: 100022 tel +86-10-5867-4080/4081 fax +86-10-5867-4090 e-mail: info-bj@hioki.cn guangzhou of?ce : room 303, pro?t plaza, no.76, west huangpu road guangzhou, p.r.china postcode: 510623 tel +86-20-38392673/2676 fax +86-20-38392679 e-mail: info-gz@hioki.cn input 8730 (1ch type) 8731 (2ch type) input terminals analog 1 channel, m3.5 screw terminals, max. rated voltage to earth: 30vrms or 60v dc (with input isolated from chassis, the maximum voltage that can be applied between input channel and chassis without damage) analog 2 channels, m3.5 screw terminals, max. rated voltage to earth: 30vrms or 60v dc (with input isolated from chassis, the maximum voltage that can be applied between input channel and chassis and between input channels without damage) measurement range (10 div full-scale) 100 mv to 5 v/div, 6 ranges, allowable ac voltage for measurement/display: 17 vrms low-pass filter: 5hz, 50hz, 500hz, 5khz, 50khz, 100khz measurement resolution data 1/160 of measurement range (using 12-bit a/d converter) max. sampling speed 1m-sample/sec (1 sec period, 8731 -10 : simultaneous 2-channels) memory capacity (number of sample data) max. 50,000 datas for each channel (12-bit 50 k-word/ch) accuracy dc amplitude: 0.5% f.s. zero position: 0.1% f.s. frequency response dc to 400khz ( 3db) input impedance/capacity 1m , 20pf (at 100 khz) maximum input voltage 30vrms or 60v dc (cat i, max. voltage that can be applied without damage between input terminals) display/interface display 7.2 inch stn color lcd (640 480 dots) measurement screen time axis screen: 1 or 2 screens x-y screen (model 8731 -10 only) : 10 div 10 div x-y axis resolution: 40 dots/div evaluation waveform evaluation on reference area (2-channel individual evaluation possible at the model 8731 -10 ) storage media pc card type ii slot, flash ata, max. 2 gb setup parameters/measurement data (binary or text) /evaluation area/screen data/processing result pc interface rs-232c (9-pin d-sub connector) , lan (10base-t) general speci?cations backup functions (at 25c/ 77f) clock and setting conditions: battery life of at least 10 years waveform data: none environmental conditions (no condensation) operation: +5c (41f) to +40c (104f) , 30% to 85% rh storage: -10c (14f) to +50c (122f) , 10% to 85% rh compliance standard safety: en61010 emc: en61326 power requirements 100 to 240v ac (50/60 hz) power consumption 40va, max. dimensions and mass 288mm (11.34in) w 144mm (5.67in) h 190mm (7.48in) d, 8730 -10 : 3.6kg (127.0oz.) 8731 -10 : 3.7kg (130.5oz.) supplied accessories instruction manual 1, power cord 1, jumper bracket 2 , external control terminal strip label 1 , application disk (wave viewer wv, communication commands table) 1 function speci?cations measurement functions memory recorder with waveform evaluation function. reference area waveform evaluation (separate 2-channels evaluation possible with the model 8731 -10 ) time axis range 100 s to 5 min/div (100 samples/div) , 20 range settings, external sampling possible up to 1khz, time axis resolution: 1/100 of range waveform expansion/ compression time axis: 10, 5, 2, 1, 1/2, 1/5, 1/10, 1/20, 1/50, 1/100, voltage axis: 10, 5, 2, 1, 1/2 recording length settable in 1 div steps, 10 to 500 div (100 points/div) waveform parameter calculation average value, peak value, maximum value, time to maximum value, minimum value, time to minimum value, rms value, cycle, frequency, rise time, fall time, area value, integer value, pulse width, duty cycle, specified level time, differential, pulse count, maximum & minimum value, (only 8731 -10 , x-y area value) waveform processing calculations four arithmetic operations, absolute value, half-wave rectification (from version 1.10 or later) other functions cursor-based measurement (a-b cursor time difference, potential difference, frequency, cursor potential, time from trigger) , scaling, variable, automatic loading of setup parameters from pc card at power-up, automatic store, overwrite, test mode store (16 setup configurations and 16 evaluation area settings can be stored in internal memory) , averaging processing (2, 4, 6, 8, 16 times) n main unit (accuracy at 23 5c/73 9f, 30 to 80 % rh after 30 minutes of warm-up time and zero-adjust; accuracy guaranteed for 1 year) trigger functions trigger sources ch1 - ch2 (only ch1 for 8730 -10 ) /external (falling edge trigger) / timer. on/off switching for each source; all off results in free-run trigger; and/or between trigger sources trigger types (analog) level: digital setting of voltage. triggered when set value is exceeded in up or down direction. window: when entering or exiting a level range defined by upper or lower limit period: when rising or falling edge of set voltage does not fall within cycle range other functions (trigger related) trigger filter (off/0.1 to 10div) , trigger level resolution (0.25% f.s., full scale = 10div) , pretrigger (0 to 100%) , trigger output (open collector, active low) external control terminals terminal type m3 screw type (isolated from chassis) , maximum rated voltage to earth: 30vrms or 60v dc (between inputs and chassis) power supply terminals maximum external input voltage v ext max: 30v dc minimum external input voltage v ext min: 5v dc internal power supply output voltage: 5v 0.5v, 40ma (total) input terminals external trigger, start, stop, external sampling, test mode select, hold, evaluation stop, multi-function ? signal level high: (v ext -1.0) to v ext [v] ? signal level low: 0 to 1.0 [v] output terminals (evaluation output available in 2 channels separately) trigger output, area evaluation 1 (pass/fail) , area evaluation 2 (pass/fail) , numeric evaluation (pass/fail) , evaluation output active, error, processing, measurement in progress, multi-function ? open collector: 0 to +30v, pull-up resistor 10k , max. sink current 140ma ? signal level high: (v ext -1.0) - v ext [v] (non-load condition) ? signal level low: 0 to 1.0 [v] evaluation output (evaluation time/evaluation cycle determined under hioki sample test conditions) evaluation mode: fail when waveform leaves area at one point/ fail when waveform is fully out of area stop conditions: ok, ng, ok & ng (waveform store at stop possible) evaluation time: 70ms max. (1-channel evaluation) , 80ms max. (2-channel evaluation) evaluation cycle: 200ms max. (1-channel evaluation) , 250ms max. (2-channel evaluation) wave comparator 8730 -10 (1ch) wave comparator 8731 -10 (2ch) ? wiring hardware for signal input m3.5 terminals and control input/output m3 terminals is not supplied. ? rack mounting capability (jis/eia) is available as special order. please contact your hioki distributor for details. lan cable 9642 supplied with cross conversion cable, straight ethernet cable, length: 5m (16.4ft) lan communicator 9333 application software to create a lan connection with windows 95/98/me, or windows nt 4.0/2000 /xp. pc card 128m 9 726 (128 mb capacity) pc card 256m 9 727 (256 mb capacity) pc card 512m 9 72 8 (512 mb capacity) pc card 1g 9 72 9 (1 gb capacity) pc card precaution u s e o n l y p c c a r d s s o l d b y h i o k i . c o m p a t i b i l i t y a n d p e r f o r m a n c e a re n o t guaranteed for pc cards made by other manufacturers. you may be unable to read from or save data to such cards. supplied with pc card adapter precaution for pc card use the pc cards listed at left can only be used in the wave comparator 8730-10/8731-10 if the firmware is ver. 1.30 or later.